6
Starting the Pump
Tooperateefcientlyandpreventpumpdamagetheremustbeafreeowofwater
to and from the pump. Before starting ensure that:
- allpipeworkiscorrectlysealed.
- thepool/spawaterlevelisatthecorrectheight.
- thatallappropriatevalvesareopenandthereisnothingpreventingtheowof
water through the system.
1. First prime the pump by ensuring that the pump is below the water level of the
spa pool.
2. Connect to the power supply or spa controller as applicable and switch on.
3. Allowthepumptorun,sothatanyairtrappedmaybeexpelled.
4. Ifprimeisnotestablishedwithinlessthanaminute,asevidencedbyastrong
owofwater,switchoffthepumpandrepeattheprocedure.
Pump Operation
The water level of the spa or spa pool should always be maintained to at least the
spajets,thusensuringwaterisinthepumpatalltimes.
Never run pump dry. Running the pump with no water may damage the
mechanical seals, causing leakage and ooding. Dry running damage and
associated damage is not covered under warranty.
Failure to undertake regular maintenance may cause damage not covered
by warranty.